501-17 Roof Opening Panel | 2013 - 2014 Fusion |
Diagnosis and Testing | Procedure revision date: 02/5/2013 |
The roof opening panel motor must be initialized when repairs are carried out on any part of the roof opening panel system or when the roof opening panel motor, glass, assembly, or air deflector has been removed or replaced for any reason.
Symptom Charts
Symptom Chart: Operation
Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices.
REFER to:
Diagnostic Methods
(100-00 General Information, Description and Operation).
Condition | Possible Sources | Actions |
---|---|---|
The roof opening panel leaks | Refer to the Pinpoint Test | |
The roof opening panel does not open or close | Refer to the Pinpoint Test | |
The one-touch open feature is inoperative |
|
|
The global open function is inoperative/does not operate correctly | Refer to the Pinpoint Test | |
The roof opening panel does not seat in flush position from any position |
|
|
Roof opening panel reverses during operation |
|
|
Symptom Chart: NVH
Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices.
REFER to:
Diagnostic Methods
(100-00 General Information, Description and Operation).
Condition | Possible Sources | Actions |
---|---|---|
The roof opening panel has excessive wind noise | Refer to the Pinpoint Test | |
The roof opening panel rattles | Refer to the Pinpoint Test | |
Roof opening panel is noisy during operation | Refer to the Pinpoint Test |
Pinpoint Tests
The Roof Opening Panel Has Excessive Wind Noise
Normal Operation and Fault Conditions
When the roof opening panel glass is completely closed, it is flush with the roof panel. The roof opening panel weatherstrip provides a seal against adverse weather conditions such as rain and wind, preventing them from entering the passenger compartment. A damaged, deformed or incorrectly installed weatherstrip is unable to effectively seal the glass. The roof opening panel air deflector deflects the air flow over the roof opening panel when the panel is in the vent or open positions, a damaged or incorrectly installed air deflector is unable to effectively deflect the air flow. An incorrectly installed roof opening panel frame may also allow air/wind to leak into the passenger compartment.
Possible Sources
Visual Inspection and Diagnostic Pre-checks
A1 VERIFY ROOF OPENING PANEL NOISE | ||||
Is the wind noise present only in the open position?
|
||||
A2 CHECK THE ROOF OPENING PANEL WEATHERSTRIP | ||||
Is the roof opening panel weatherstrip OK?
|
||||
A3 CHECK ROOF OPENING PANEL ALIGNMENT | ||||
Is the alignment OK?
|
||||
A4 CHECK THE AIR DEFLECTOR | ||||
Is the air deflector OK?
|
The Roof Opening Panel Leaks
Normal Operation and Fault Conditions
When the roof opening panel glass is completely closed, it is flush with the roof panel. The roof opening panel weatherstrip provides a seal against adverse weather conditions such as rain and wind, preventing them from entering the passenger compartment. A damaged, deformed or incorrectly installed weatherstrip is unable to seal the glass efficiently. The roof opening panel trough assembly and drain hoses provide a route for water to drain away from the opening panel, damaged or obstructed drain hoses or trough assembly will allow water to collect and possibly leak into the passenger compartment.
NOTE: Water may accumulate on both outside front corners of the glass panel after rain or after a car wash. If the glass panel is opened with water in the front corners, this water will fall into the channel for the glass panel track (which is not sealed) and down into the headliner. If the source of a suspected leak cannot be determined, this situation may be the source. This is a normal condition, do not replace any part of the roof opening panel system due to this condition.
Possible Sources
Visual Inspection and Diagnostic Pre-checks
B1 CHECK THE ALIGNMENT OF THE ROOF OPENING PANEL | ||||
Does the roof opening panel seal correctly?
|
||||
B2 CHECK THE ROOF OPENING PANEL DRAIN HOSES | ||||
Are the roof opening panel drain hoses OK?
|
||||
B3 CHECK THE ROOF OPENING PANEL DRAIN HOSE ATTACHMENT POINTS | ||||
Are the roof opening panel drain hose attachment points OK?
|
||||
B4 CHECK THE ROOF OPENING PANEL REAR TROUGH CONDITION | ||||
Is the roof opening panel trough OK?
|
||||
B5 CHECK THE CONDITION OF THE ROOF OPENING PANEL FRAME | ||||
Is the roof opening panel frame OK?
|
The Roof Opening Panel Rattles
Normal Operation and Fault Conditions
When the roof opening panel glass is completely closed, it is flush with the roof panel. All components should be secured correctly. The roof opening panel system is made up of many components that require specific torque specifications and correct installation in order to avoid any NVH concerns. Over time, components may become loose or damaged, fasteners may become loose, sound insulating material may wear out and foreign material may collect in the roof opening panel frame. It is possible that one or more of these conditions may lead to a rattle concern in the roof opening panel system.
Possible Sources
Visual Inspection and Diagnostic Pre-checks
C1 CHECK THE ROOF OPENING PANEL WEATHERSTRIP | ||||
Is the roof opening panel weatherstrip OK?
|
||||
C2 CHECK THE ROOF OPENING PANEL TIGHTNESS | ||||
Is the roof opening panel loose?
|
||||
C3 CHECK THE ROOF OPENING PANEL TRACKS | ||||
Are the roof opening panel tracks OK?
|
||||
C4 CHECK THE ROOF OPENING PANEL TROUGH AND TROUGH GUIDES | ||||
Are the roof opening panel trough and trough guides installed securely and free from obstructions?
|
||||
C5 CHECK THE ROOF OPENING PANEL SHIELD (SUNSHADE) | ||||
Is the roof opening panel shield installed correctly?
|
||||
C6 CHECK THE ROOF OPENING PANEL AIR DEFLECTOR ASSEMBLY | ||||
Is the roof opening panel air deflector assembly OK?
|
||||
C7 CHECK THE ROOF OPENING PANEL GLASS | ||||
Is the roof opening panel glass OK?
|
||||
C8 CHECK THE ROOF OPENING PANEL LIFTER ASSEMBLIES | ||||
Are the roof opening panel lifter assemblies OK?
|
||||
C9 CHECK ROOF OPENING PANEL FRAME INSTALLATION | ||||
Is the roof opening panel correctly installed and tightened to specification?
|
||||
C10 CHECK THE ROOF OPENING PANEL FRAME FOR RATTLES | ||||
Is there a condition that will cause rattles?
|
The Roof Opening Panel is Noisy During Operation
Normal Operation and Fault Conditions
When the roof opening panel glass closes, it should do so quietly and smoothly. The roof opening panel system is made up of many components that require specific torque specifications and correct installation in order to avoid any NVH concerns. Over time, components may become loose or damaged, fasteners may become loose, sound insulating material may wear out and foreign material may collect in the roof opening panel frame. It is possible that one or more of these conditions may lead to a noise concern in the roof opening panel system.
Possible Sources
Visual Inspection and Diagnostic Pre-checks
D1 CHECK THE ROOF OPENING PANEL FOR OBSTRUCTIONS OR DAMAGE | ||||
Are there any obstructions and/or damage?
|
||||
D2 CHECK THE ROOF OPENING PANEL OPERATION | ||||
Is the roof opening panel loose or incorrectly aligned?
|
||||
D3 CHECK THE ROOF OPENING PANEL TRACKS | ||||
Are the roof opening panel tracks OK?
|
||||
D4 CHECK THE ROOF OPENING PANEL SHIELD | ||||
Is the roof opening panel shield moving correctly?
|
||||
D5 CHECK THE ROOF OPENING PANEL LIFTER ASSEMBLIES | ||||
Are the roof opening panel lifter assemblies OK?
|
||||
D6 CHECK THE ROOF OPENING PANEL MOTOR/MODULE | ||||
Does the motor/module make excessive noise?
|
The Roof Opening Panel Does Not Open or Close
Refer to Wiring Diagrams Cell 101 for schematic and connector information.
The roof opening panel motor must be initialized when repairs are carried out on any part of the roof opening panel system
or when the roof opening panel motor, glass, assembly, or air deflector has been removed or replaced for any reason.
REFER to:
Power Roof Opening Panel Initialization
(501-17 Roof Opening Panel, General Procedures).
Normal Operation and Fault Conditions
The roof opening panel motor/module receives voltage from the accessory delay relay when the ignition is in the ACC or RUN position. The roof opening panel control switch (part of the overhead console) supplies ground signals to the roof opening panel motor/module to operate the roof opening panel. A failure in the power, ground, or control circuits, an internal failure of the switch or motor/module or a motor/module that has not been initialized all cause the roof opening panel to become inoperative.
Possible Sources
Visual Inspection and Diagnostic Pre-checks
E1 CHECK THE ROOF OPENING PANEL OPERATION | ||||||||||||||||
Does the roof opening panel operate to the vent position?
|
||||||||||||||||
E2 CHECK THE MOTOR/MODULE FOR INITIALIZATION | ||||||||||||||||
Is the concern still present?
|
||||||||||||||||
E3 CHECK THE POWER WINDOWS | ||||||||||||||||
Do the power windows operate?
|
||||||||||||||||
E4 CHECK THE ROOF OPENING PANEL MOTOR/MODULE VOLTAGE SUPPLY | ||||||||||||||||
Is each voltage within 0.2 volt of battery voltage?
|
||||||||||||||||
E5 CHECK THE ROOF OPENING PANEL MOTOR GROUND CIRCUIT FOR AN OPEN | ||||||||||||||||
Is the resistance less than 3 ohms?
|
||||||||||||||||
E6 CHECK ROOF OPENING PANEL CONTROL SWITCH TO ROOF OPENING PANEL MOTOR CIRCUITS FOR AN OPEN | ||||||||||||||||
Are the resistances less than 3 ohms?
|
||||||||||||||||
E7 CHECK THE ROOF OPENING PANEL CONTROL SWITCH GROUND CIRCUIT FOR AN OPEN | ||||||||||||||||
Is the resistance less than 3 ohms?
|
||||||||||||||||
E8 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR CORRECT OPERATION | ||||||||||||||||
Is the concern still present?
|
The Global Open Function is Inoperative/Does Not Operate Correctly
Refer to Wiring Diagrams Cell 101 for schematic and connector information.
The global open feature may be enabled/disabled via scan tool or in some cases modified by the customer following a procedure
listed in the vehicle Owner's Literature. For a complete list of available programmable parameters, refer to the Module Configuration
and Parameter Chart.
REFER to:
Module Configuration - System Operation and Component Description
(418-01 Module Configuration, Description and Operation).
The roof opening panel motor must be initialized when repairs are carried out on any part of the roof opening panel system
or when the roof opening panel motor, glass, assembly, or air deflector has been removed or replaced for any reason.
REFER to:
Power Roof Opening Panel Initialization
(501-17 Roof Opening Panel, General Procedures).
Normal Operation
When the global open feature is activated, the sends a signal to the roof opening panel motor to place the roof opening panel in the vent position. The global open feature does not function when the delayed accessory is active. Any interference in the circuit or the window motor may cause the global open feature to not operate correctly.
Possible Sources
Visual Inspection and Diagnostic Pre-checks
F1 VERIFY THE POWER WINDOWS ARE OPERATIONAL | ||||||||||
Do the power windows operate correctly?
|
||||||||||
F2 | ||||||||||
Is the resistance less than 3 ohms?
|
Copyright © Ford Motor Company